Rice Husk Burner |
|
Left movie shows how the rice husk
is burnt through the specially designed rice husk burner.(Patented). Preheated air from the air-preheater comes into the burnber with swirling cyclone effect
to spray rice husk into the high temperature furnace and there 70-80% rice husk burns in suspension and remaining unburnt rice husk will fall
onto the heavy duty chain grate installed at the bottom of the furnace. This system has proven its highest efficiency in burning rice husk. |
|
|
|
|
Rice Husk Delivery by the river in Vietnam |
|
|
|
|
|
|
Chain Grate Boimass Boiler |
|
|
Calofic-CAI LAN-CAN THO (Vietnam) |
Rice Husk Boiler Fuel Gas Analysis
|
No |
Date |
Rice Husk
Consmption (Kg) |
Steam Flow (Ton) |
Rice Husk Consumption
per-Ton Steam
(Kg/Ton-Steam) |
1 |
2008-02-28 |
34922.0 |
137.8 |
253.4 |
2 |
2008-02-29 |
39441.0 |
153.0 |
257.8 |
3 |
2008-03-01 |
37795.0 |
152.0 |
248.7 |
4 |
2008-03-02 |
34659.0 |
156.8 |
221.0 |
5 |
2008-03-03 |
6259.0 |
79.1 |
79.1 |
6 |
2008-03-04 |
35837.0 |
154.9 |
231.4 |
7 |
2008-03-05 |
36600.0 |
149.2 |
245.3 |
8 |
2008-03-06 |
36614.0 |
178.0 |
205.7 |
9 |
2008-03-07 |
37571.0 |
163.4 |
229.9 |
10 |
2008-03-08 |
38982.0 |
165.3 |
235.8 |
11 |
2008-03-09 |
38940.0 |
162.0 |
240.4 |
12 |
2008-03-10 |
38803.0 |
158.7 |
244.6 |
13 |
2008-03-11 |
39006.0 |
165.3 |
236.0 |
14 |
2008-03-12 |
38752.0 |
173.9 |
222.9 |
15 |
2008-03-13 |
38877.0 |
171.95 |
226.1 |
16 |
2008-03-14 |
39204.0 |
170.0 |
230.6 |
|
|
This is the rice husk consumption record and exhoust flue gas emission test.
Rice husk consumption average : 240 Kg/ton Steam.
Particle, SOx and NOx are all within the Vietnam government set regulation as shown in the test report. |
|
Flue Gas-Hamada Boiler Guarantee and VIETNAM GOVERNMENT RULE; |
NO |
ITEM |
VALUE |
1 |
Particle |
350mg/m3 |
2 |
NO2 |
400mg/m3 |
3 |
SO2 |
500mg/m3 |
|
Flue Gas-Hamada Boiler Guarantee ACTUAL TEST RECORD |
NO |
ITEM |
VALUE |
1 |
Particle |
92.89mg/m3 |
2 |
NO2 |
24.664mg/m3 |
3 |
SO2 |
34.744mg/m3 |
|